Programming by console
Installer Manual -
TP8-64 BUS
5-28
MENU
14
14
14
14
14
Beg. alarm Z
Zone 001
Zone 001
Channel A
[ ]
Report code
31
Menu
14
Ass. alarms
5.15
ASSOCIATION OF THE EVENTS TO THE CHANNELS
+
yw
to select the menu (14)
+
#
YES
to confirm the selection
Every channel can be programmed so as to transmit every kind of event collected by
the control panel:
z
Beg. alarm Z
z
End tamper
z
Panic
z
End alarm Z
z
Beg.trouble M
z
Beg. masking
z
Beg. alarm P
z
End trouble M
z
End masking
z
End alarm P
z
Low battery
z
Beg. superv.
z
Arming P
z
Battery ok
z
End superv.
z
Disarming P
z
Power failure
z
Cut tel. line
z
Act. byp
z
Mains ok
z
Tel. line ok
z
Dis byp
z
False access
z
Test call
z
Exclusion Z
z
Hold-up code
z
Timer reset
z
Beg. tamper
z
Conf. dis.
z
Download ev.
Commands available
+
yw
to select the event
+
#
YES
to confirm the selection
+
EXIT
to accept programming and quit the submenu
5.15.1
ZONE RELATED EVENTS
SELECTION OF THE ZONE
+
yw
to select the zone (from 1 to 64)
+
#
YES
to confirm the selection
CHANNEL ASSOCIATION
+
yw
to select the channel (A...H)
Viewing of the current settings
[ ] Channel not associated to the event selected
[ # ] Channel associated to the event selected
Commands available
+
0
to pass directly onto the report code configuration
+
#
YES
to associate the channel to the event
+
*
NO
to undo the association
+
EXIT
to accept programming and quit the submenu
PROGRAMMING OF THE REPORT CODE
+
yw
to select the parameter
Every event can be associated a different report code to (for the digital communication
with central monitoring stations). The report code is a 2-digits alphanumeric code
(from 00 to FF).
Commands available
+
yw
to delete an existing code
+
#1
to insert the character A
+
#2
to insert the character B
+
#3
to insert the character C
+
#4
to insert the character D
+
#5
to insert the character E
+
#6
to insert the character F
+
0
...
9
to insert number values
+
EXIT
to accept programming and quit the submenu
5.15.2
PROGRAM RELATED EVENTS
SELECTION OF THE PROGRAM
+
yw
to select the program (from 1 to 8)
+
#
YES
to confirm the selection
CHANNEL ASSOCIATION
+
yw
to select the channel (A...H)
Viewing of the current settings
[ ] Channel not associated to the event selected
[ # ] Channel associated to the event selected
Report code
51
Beg. alarm P
Program 01
Program 01
Channel A
[ ]
Summary of Contents for TP8-64 BUS
Page 4: ...IV Installer Manual TP8 64 BUS...
Page 12: ...Index Installer Manual TP8 64 BUS 8...
Page 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Page 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Page 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Page 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Page 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Page 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Page 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Page 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Page 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Page 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Page 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Page 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Page 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Page 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Page 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Page 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Page 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Page 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Page 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Page 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Page 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...