Chapter 1. Product Information
EK–MOL80–SV. B01
1–7
Cooling requirements
15 CFM bi-directional
through drive
Power Requirements
Line voltage
100-240V
Line frequency
50-60Hz
Power consumption (typical)
240 W
819.1 BTU
Power consumption (maximum)
275 W
938.5 BTU
Service Characteristics
Mean time between failure
80,000 power-on hours
Mean swaps between failure
600,000
Mean time to repair
30 minutes
Preventive maintenance
none required
Product Certifications
Safety
EN 60950/IEC 950
UL 1950 listed or recognized
CSA 950- TUV approved to VDE 0805 05.90
Electromagnetic emissions
FCC 47 CFR Part 15 Subpart J - Class "B" EN
55022/CISPR 22, Level"B";SABS
VCCI Level 2
Laser
CDRH 21 CFR Chapter 1, Subpart J
Registered IEC 825
TUV approved to VBG93, VDE 0837
TTL to Decision 472
BS 4803 part 2 Approved
Optical Disks
1X
2X
4X
Formatted Capacity
1,024-byte sectors
650 Mbytes
1.3 GBytes
2.6 GBytes
512-byte sectors
594 Mbytes
1.2 GBytes
2.3 GBytes