Chapter 3. Product Configuration and Operation
EK–MOL80–SV. B01
3–5
Table 3–2 SCSI Cable Length Limitations
Interface Type
Allowable Cable Length
Single-Ended SCSI
6 meters
Differential SCSI
15 meters
NOTE
Because of signal delays inside the jukebox,
the allowable external cable length for
differential SCSI interface mode is limited to
15 meters instead of the 25 meters typically
available with a differential SCSI bus.
There are two methods of connecting the jukebox to the host computer:
•
as the only peripheral device connected to your computer with a SCSI cable.
•
as one of a number of peripheral devices connected to the computer with a
SCSI cable.
Connecting Power
1. Check to make sure that the standby power switch located on the right end
of the jukebox is OFF.
NOTE
The switch located on the right end of the
jukebox, frequently referred to as a "power
switch" only supplies the logic switch to
electronics in the power distribution PCA to
enable the 5/12V supplies. It does not
physically control input power.
2.
Remove the panel on the lower left end of the jukebox. Plug the power cord
into the AC line connector located on the bottom of the interface module.
(Figure 3–2.)