Chapter 4. Troubleshooting and Diagnostics
EK–MOL80–SV. B01
4–19
Table 4–3 Hardware Errors and Recovery Procedures (
continued
)
Error Code
Error Description
Recovery Procedures
(hex.)
41
Test magazine
Failed testing the magazine portion
during an ISTAT.
•
Look at the micro-move error of
the failure in the error log (under
INFO*, and Hardware Error in
the control panel display).
•
Probably the picker.
42
Put drive in
•
Look at the micro-move error of
the failure in the error log (under
INFO*, and Hardware Error in
the control panel display).
•
Remove rear panel and run the
Wellness Test, Drive I/O test,
and Exercise Mechanics test.
Note where the problem occurs.
•
If indicates the drive, change the
drive.
•
If it indicates a picker error,
change the picker.
43
Get drive out
•
Look at the micro-move error of
the failure in the error log (under
INFO *, and Hardware Error in
the control panel display).
•
Remove rear panel and run the
Wellness Test, Drive I/O test,
and Exercise Mechanics test.
Note where the problem occurs.
•
If indicates the drive, change the
drive.
•
If it indicates a picker error,
change the picker.