Medium Optical Disk (RW551/RW552) Library
4–10
EK–MOL80–SV. B01
Table 4–2 Operation Errors (
continued
)
Task
Problem/Symptom
What to do
Loading Disks
Disk inserted in mailslot,
but the display reads
LOAD ERROR, or
MISLOAD.
Remove the disk from the
mailslot and try inserting it
again. Push the disk in,
shutter-end first, so that the
disk is flush with the jukebox
front panel.
Powering on
The optical disk jukebox
won't power on.
•
Check to make sure the
power cord connections
are tight.
•
Check that the power
switch is ON (next to
the mailslot).
•
Check to make sure the
power outlet is
operating.
•
Replace the power cord
with a known good one.
•
Replace the power
supply module.
Power on selftest fails.
•
Press ENTER and
record the error
message.
•
Cycle the power.
Observe the power on
test result. If the unit
continues to fail, use
the error code to begin
troubleshooting. (See
the "Power on Selftest"
section following this
table.)
Power fail
Just the autochanger
power fails.
When power returns,
unmount and remount all disk
surfaces. Do not eject any
disks until the surfaces are
umounted/unreserved.