Medium Optical Disk (RW551/RW552) Library
4–34
EK–MOL80–SV. B01
Running an Internal Test
CAUTION
Some diagnostic tests can corrupt the file system
if a test is not properly completed.
1.
With
READY
displayed, press NEXT until
ADMIN*
appears in the display
window.
NOTE
A three-part security code is required to access
any options beneath ADMIN. The security code is
set to 0,0,0 at the factory, but you should
encourage the customer to change this as soon
as possible to avoid access by unauthorized
persons.
2.
Press
ENTER. CODE1
and a flashing 0
displays.
Press
ENTER
if no security
code has been set, otherwise press
NEXT
until the first number of the security
code displays, and then press ENTER. Repeat this step to enter the next two
parts of the security code.
3.
TEST*
displays.
Press ENTER.
4.
Press NEXT until the name of the test you wish to run displays and then
press.
Descriptions of the available internal tests are on the following pages.
Table 4–5 Available Internal Tests for the RW551 and RW552
Test Name
Description
EXCHANGE DEMO
DO NOT RUN THIS TEST!! This test moves
randomly-chosen cartridges to random storage
slot locations. Do not run this test if the jukebox
contains disks with actual file system data on
them. This test displays
FAIL
if there are no
disks in the jukebox or if all storage slots are full.
The drives and mailslot must be empty.
INIT MECHANICS
Runs the FIND PLUNGE HOME, FIND
VERTICAL HOME, FIND XLATE HOME, INIT
ELEM STATUS tests, and then rotates the
mailslot
out. Each test is run one time per test loop.