Chapter 4. Troubleshooting and Diagnostics
EK–MOL80–SV. B01
4–17
Table 4–3 Hardware Errors and Recovery Procedures (
continued
)
Error Code
Error Description
Recovery Procedures
(hex.)
29
Right beam error
•
Check that the space between
the picker and magazines is
physically clear.
•
Run the STARWARS test to
verify that there is a beam on
the right side and the indication
changes properly when the
beam is interrupted. If the
STARWARS test can not verify
the beam, change the
interposer PCA.
•
Change the controller PCA
(receivers are mounted on this
PCA).
2A
Left beam error
See error 29 (apply to left beam).
2B
Top thumb sensor error
•
Change the picker
•
Change the umbilical cable
•
Change the controller PCA
2C
Bottom thumb sensor
error
•
Change the picker
•
Change the umbilical cable
•
Change the controller PCA
32
Invalid test number
User error
33
Invalid configuration
User error
34
Need to initialize element
status
Run Init Elem Status
35
Exercise test failed
Run Exercise test again, watch
where it fails.
36
Elements reserved
User error