Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
455
100818 Extended output block
Description
The block is used for expanded access to binary outputs BA1 to BA10 and analog outputs AA1 and AA2. The
block offers several parameters.
When an existing parameter is entered in
F61
, the parameter is read, passed through switchon delay (
F80
BA1 on delay) and switchoff delay (
F81
BA1 off delay) as well as inversion (
F82
BA1 inverting) and is then
output to binary output BA1.
When an existing parameter is entered in
F62
, the parameter is read, passed through switchon delay (
F83
BA2 on delay) and switchoff delay (
F84
BA2 off delay) as well as inversion (
F85
BA2 inverting) and is then
output to binary output BA2.
When the coordinate of a parameter is specified in
F63
to
F70
, this is read and its current value is output to
the applicable binary output.
When the coordinate of a parameter is specified in
F40
analog-output1-source, this is read, multiplied by
F42
analog-output1-gain and then
F41
analog-output1-gain added. Next comes a low-pass filter of the first order
with
F43
analog-output1-act low pass filter, followed by an amount block (if
F44
analog-output1-absolute is
activated) and output to the analog output.
At the same time display parameter
E16
analog-output1-level is updated.
When the coordinate of a parameter is specified in
F50
analog-output2-source, this is read, multiplied by
F52
analog-output2-gain and then
F51
analog-output2-gain added. Next comes a low-pass filter of the first order
with
F53
analog-output2-act low pass filter, followed by an amount block (if
F54
analog-output2-absolute is
activated) and output to the analog output.
At the same time display parameter
E28
analog-output2-level is updated.
NOTE
When a parameter of a data type with 8 bits, 16 bits or 32 bits is specified in
F61
to
F70
, the first byte of this
parameter is evaluated. When the value of the byte is 0, the signal 0:inactive is output to the binary output.
When the value of the byte is not 0, signal 1:active is indicated on the binary output.
Remember that binary outputs BA3 and BA10 are only available with option module XEA (MDS 5001) or LEA
(FDS 5000).
NOTE
It is only useful to specify a format I16 parameter in
F40
or
F50
.
When
F40
or
F50
specifies a parameter of the 8-bit data type, the next-to-less-significant, even-numbered
addresses are read and the 8-bit value can appear in the MSB or LSB of the analog output.
When
F40
or
F50
specifies a parameter of the 32-bit data type, the MSW (bits 31 to 16) is read and output.
NOTE
Remember that outputs with inverter MDS 5000 are only available with one of the options SEA 5000,
REA 5000 or XEA 5001.
With inverter FDS 5000 binary outputs BA3 to BA10 are only available with the option LEA 5000.
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...