System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
29
4 Square root 16Bit
Description
The block calculates the square root of the value on the input
In
. The result is written to the
output
Out
and rounded to the next lower whole number. When the input value is a negative
value, the block sets the result on
Out
to zero.
Inputs
No. Name
Datatype Scaling
Description
1
In
I16
–
Value whose square root is calculated
Outputs
No. Name
Datatype Scaling
Description
2
Out
I16
–
Square root of the value on the input
In
Summary of Contents for POSIDRIVE MDS 5000