Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
334
100012 X100.AE2
Description
The block writes the current value of the analog input to the display parameter
E11
AE2-Level. The
value is added to
F21
AE2-Offset and multiplied by
F22
AE2 Gain. The result is output to
Out
.
(AE2-Level +
F21
) x
F22
=
Out
Outputs
No. Name
Datatype Scaling
Description
1
Out
I16 16384=10V
Level of the analog input AE2 calculated with
F21
AE2-Offset and
F22
AE2 Gain (terminal X100.4-X100.5)