System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
150
137 Square root R32
Description
The block calculates the square root of the value on the input
In
. The result is written to the
output
Out
. When an input value is negative, the result is undefined.
Inputs
No. Name
Datatype Scaling
Description
1
In
R32
–
Input value whose square root is to be calculated
Outputs
No. Name
Datatype Scaling
Description
2
Out
R32 –
Result