Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
432
100501 Techology controller input block
Description
The block generates the control signals for the technology controller application from the
analog inputs, binary inputs or from fieldbus process data.
NOTE
The block is automatically used in the configuration of the axis if you generate the
technology controller application.
Outputs
No. Name
Datatype Scaling
Description
1
TechRefV
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
G132
source technology reference value (analog input or
G232
).
The technology controller application uses the output to show the
state of the technology controller reference value.
2
TechActV
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
G133
source actual technology value (analog input or
parameter from
G12
).
The technology controller application uses the output to show the
state of the technology controller actual value.
3
TecRVneg
B –
The output supplies the state of the source which was specified by the
parameter
G100
source negate technology reference value (binary
input or
G210
bit 2).
The technology controller application uses the signal to negate the
technology reference value.
4
PID off
B –
The output supplies the state of the source which was specified by the
parameter
G101
source PID controller disable (binary input or
G210
bit 3).
The technology controller application uses the signal to switch off the
PID controller.
5
RVrelat.
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
D130
reference value source (analog input or
D230
).
The technology controller application uses the signal as a high-
resolution reference value.
6
MaxTorqu
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
C130
torque limit source (analog input or
C230
).
The technology controller application uses the signal as the torque
limit.
7
Reverse
B –
The output supplies the state of the source which was specified by the
parameter
D100
reverse source (binary input or
G210
Bit 0).
The technology controller application uses the signal to negate the
reference value.
8
ExtFault
B –
The output supplies the state of the source which was specified by the
parameter
D101
external fault source (binary input or
G210
bit 1).
The technology controller application uses the signal to trigger a fault
externally.
9
PIDModEn
B –
The output supplies the state of the source which was specified by the
parameter
G102
source PID controller set (binary input or
G210
bit 4).
The technology controller application uses the signal to set the PID
controller to the preset value.
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...