Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
423
100435 Master motion block posi
Description
The block integrates blocks 100255 and 100227. It offers a way to internally
generate the speed feed forward of the master signal or to specify it via the
signal on the input
SpdFdFwd
(16384 = 1.0 *
C01
). Parameter
G31
handles
the switch from internal to external feed forward.
NOTE
The block is automatically used in the configuration of the axis when you
generate the command positioning application with limited or endless position
range.
Inputs
No. Name
Datatype Scaling
Description
6
GeaRatio
I16
16383 = 1,0
Online modification of the gear ratio
16384 and 16383 = 1.0
7
SpdFdFwd
I16
16383 = 1,0 ×
C01
External speed feed forward
16384 = 1.0 *
C01
Outputs
No. Name
Datatype Scaling
Description
1
MstrRawR
I32
–
Master encoder raw value for referencing
2
XMstrLim
P64
Skal.-Fkt. 19
Actual master position for limited position range
3
XMstrEnd
P64
Skal.-Fkt. 19
Actual master position for endless position range
4
XMstrTS
U16
1LSB = 1us
Timestamp of the actual master position
5
MstrVel.
I32
Skal.-Fkt. 20
Master speed
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...