System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
129
100 Dead zone I16
Description
The block implements a deadband.
When the input variable
In
is greater than or equal to zero and smaller than or equal
to the value on the input
Deadband
, the output
Out
is zero.
When the input variable
In
is greater than or equal to zero and greater than the value
on the input
Deadband
, the output
Out
is
In - Deadband
.
When the input variable
In
is less than or equal to zero and greater or equal to the
value on the input
Deadband
, the output
Out
is zero.
When the input variable
In
is less than or equal to zero and less than the negated
value on the input
Deadband
, the output
Out
is
In + Deadband
.
Inputs
No. Name
Datatype Scaling
Description
1
In
I16
–
Input value which is to be calculated with the deadband
2
Deadband
I16
–
Deadband which is set
Outputs
No. Name
Datatype Scaling
Description
3
Out
I16
–
Output of the input value under consideration of the set deadband