33 priority encoder 2 Bit
Description
The number of the active input with the highest priority is output to the output. The priority is
defined in ascending order starting with
In0
.
Inputs
No. Name
Datatype Scaling
Description
1
In0
B
–
Binary input signal
2
In1
B
–
Binary input signal
3
In2
B
–
Binary input signal
4
In3
B
–
Binary input signal
Outputs
No. Name
Datatype Scaling
Description
5
Out
U8 –
Significance of the active input signal with the highest priority
(In0 = lowest priority)