Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
362
100151 X103.BE11
Description
The block shows the signal state of binary input BE11. It outputs it to the output
Out
and copies it to
the related bit of
E19
binary inputs.
E19
binary inputs:
Bit 0:
X1.Enable
Bit 1:
X100.BE1
And so forth
Bit 13:
X100.BE13
NOTE
Remember that binary input BE11 is only available when option module XEA (MDS 5000) or LEA
(FDS 5000) is used.
Outputs
No. Name
Datatype Scaling
Description
1
Out
B
–
Status of binary input BE11 (terminal X103.14)
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...