Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
350
100093 DP-V1 Rx Mapping
Description
The block handles cyclic data communication with PROFIBUS. The PDO type configured for this drive on the
PROFIBUS master determines the number of bytes which are received. The bytes are automatically copied to
the selected target parameters as per variable PZD mapping (see parameters
A90
,
A91
). In addition, this
block handles communication of the cyclic data to the PKW0 routine and sends the data processed by the
parameter values of block 100094.
NOTE
Since block 100094 must be instanced before the data processed by block 100094 can be sent, always use
blocks 100093 and 100094 together.
From the view of the PROFIBUS master, the configuration of the drive must be coordinated with the
parameters
A90
and
A91
.