Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
508
100928 Digital inputs 1
Description
The block generates the control signals from the binary inputs or from control word
D211
for
the comfort reference value application.
The output of the value to the output
MainRSel
is updated based on a level or edge-
triggered enable. The source of the edge-triggered enable is set in
D119
edge enable main
ref value source (binary input or
D211
bit 10). The source for level-triggered enabling is
selected in parameter
D120
level enable main ref value source (binary input or
D211
bit
11). Both enables can be parameterized with switchon and switchoff delay (
D419
.x and
D420
.x).
The block updates the monitoring parameters
D319
and
D320
.
NOTE
The block is used automatically in the configuration of the axis if you generate the comfort
reference value application.
Outputs
No. Name
Datatype Scaling
Description
1
MPUp
B –
The output supplies the state of the source which was specified by the
parameter
D114
motorised pot up source (binary input or
D211
bit 0).
The comfort reference value application uses the signal to increment
the motor pot reference value.
2
MPDown
B –
The output supplies the state of the source which was specified by the
parameter
D115
motorised pot down source (binary input or
D211
bit
1).
The comfort reference value application uses the signal to decrement
the motorized pot reference value.
3
MPPreset
B –
The output supplies the state of the source which was specified by the
parameter
D116
motorised pot preset source (binary input or
D211
bit
2).
The signal can be parameterized with a switchon or switchoff delay in
parameters
D416
.x. The comfort reference value application uses the
signal to set the motorized pot reference value to the Preset value.
4
MPRmpSel
B –
The output supplies the state of the source which was specified by the
parameter
D117
motorized pot ramp source (binary input or
D211
bit
3).
The signal can be parameterized with a switchon or switchoff delay in
parameters
D417
.x. The comfort reference value application uses the
signal to switch between the ramps
D41
and
D42
of the motorized pot
reference value when bit 7 of
D40
is active.
5
TecRVNeg
B –
The output supplies the state of the source which was specified by the
parameter
G100
source negate technology reference value (binary
input or
D211
bit 4).
The comfort reference value application uses the signal to negate the
technology reference value.
6
PIDOff
B –
The output supplies the state of the source which was specified by the
parameter
G101
Source PID controller disable (binary input or
D211
bit 5).
The comfort reference value application uses the signal to switch off
the PID controller.
7
PIDModEn
B –
The output supplies the state of the source which was specified by the
parameter
G102
source PID controller set (binary input or
D211
bit 6).
The comfort reference value application uses the signal to initialize
the PID controller.
8
MainRSel
U8 –
The output supplies the state of the sources which were specified in
parameters
D118.0
to
D118.3
combined into one U8 value (binary
input or
D211
bit 7 to bit 9).
The comfort reference value application uses the signal to indicate the
main reference value selector.
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...