149 Limiter I32
Description
The block limits the value on the input
In
(data format I32) to the value range between
Lim+
and
Lim-
. When an input value is outside the limits
Lim+
and
Lim-
, the exceeded limit value
is output to
Out
and the outputs
Lim+
and
Lim-
are set accordingly.
NOTE
The block can only execute the limitation correctly when the value on
Lim+
is greater than
Lim-
.
Inputs
No. Name
Datatype Scaling
Description
1
In
I32
–
Value to be limited
2
Lim+
I32
–
Upper limit value
3
Lim-
I32
–
Lower limit value
Outputs
No. Name
Datatype Scaling
Description
4
Out
I32 –
Limited value. When the input value on
In
is outside the limits
Lim+
and
Lim-
, the exceeded limit value is output.
5
Lim+
B –
Status of upper limit:
0 = upper limit
Lim+
was not exceeded.
1 = upper limit
Lim+
was exceeded.
6
Lim-
B –
Status of lower limit:
0 = lower limit
Lim-
was not exceeded.
1 = lower limit
Lim-
was exceeded.
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...