Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
534
100955 Analog input signals
Description
This block generates the analog control signals from the analog inputs or from fieldbus
process data for the comfort reference value application.
The analog inputs use the scaled blocks 100807 X100.AE1, 100808 X100.AE2, and
100809 X100.AE3 which are only calculated for selected sources (enable parameter for
100807:
D229.30
, for 100808:
D229.31
and for 100809:
D229.32
).
The values of analog input AE1 are monitored for wire break when
F14
=
3: 4mA to 20mA
or
F14
=
4: 20mA to 4mA
and wire break monitoring was activated in
F15
.
NOTE
The block is used automatically in the configuration of the axis if you generate the comfort
reference value application.
Outputs
No. Name
Datatype Scaling
Description
1
RefV
I32
16384 = 1Upm
The output supplies the state of the parameter
D231
high-resolution
reference value
2
RefVRel
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
D132
reference external source (analog input or
D232
).
3
CRefV1
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
D133
correction ref value 1 source (analog input or
D233
).
4
CRefV2
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
D134
correction ref value 2 source (analog input or
D234
).
5
JogRef
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
D135
jog ref value source (analog input or
D235
).
6
TechRefV
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
G132
source technology reference value (analog input or
G232
).
7
TechActV
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
G133
source actual technology value (analog input or
parameter entered in
G12
).
8
MaxTorq1
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
C130
torque limit source (analog input or
C230
).
9
MaxTorq2
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
C131
torque limit 2 source (analog input or
C231
).
10
MaxTMot
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
C132
torque limit motoring source (analog input or
C232
).
11
MaxTGen
I16
16384 = 100%
The output supplies the state of the source which was specified by the
parameter
C133
torque limit generating source (analog input or
C233
).
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...