System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
74
45 Integrator with saturation I32
Description
The block continuously integrates the input variable
In
and writes the result to the output
Out
.
IntTime
is the time in µs which the output needs to reach the value of the input with
a constant input variable.
Integration is performed within the value range of data format I32. When the output
reaches the upper limit of validity, signal level 1 is written to the binary output
SatU
.
When the limit of the negative value range is reached, signal level 1 is written to the
output
SatL
. In both cases, the output value is saturated. It remains unchanged until an
integration in the opposite direction takes place. When the integration results in a value
within the value range,
SatU
or
SatL
are reset.
Inputs
No. Name
Datatype Scaling
Description
1
In
I32
–
Value to be integrated
5
IntTime
U32
1LSB = 1us
Time until the output
Out
reaches the input value
In
. Unit: ms
Outputs
No. Name
Datatype Scaling
Description
2
Out
I32
–
Result of the integration
3
SatU
B
–
Indication of an overflow of the data area I32 due to integration
4
SatL
B
–
Indication of an underflow of the data area I32 due to integration
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...