Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
565
101058 Master-Filter
Description
This block filters the actual master position and increases the resolution if
desired.
The circular length for endless axes is also automatically converted.
The resolution increase can be specified via
IncMul
as a power of two. If, for
example,
IncMul
is 3, the position is multiplied by a factor of 2 to the 3rd
power = 8.
Enable
activates the filter. When inactive, increment multiplication is also
disabled.
Initialization:
The block automatically performs an initialization cycle when
Enable
changes from FALSE to TRUE. Initialization can also be triggered by
Reset
.
This immediately sets the low passes to the input values. The output values
are derived from the multiplication of the input values.
A time constant
T
must be specified for position and speed for the low
passes.
T
is scaled with the following formula:
]
[
150
]
[
*
65536
ms
CycletimeA
ms
Tau
e
T
−
=
(Tau and cycle time in ms)
When a parameter is defined for
T
, you can use the definition of
C43
, for
example.
When
Reset
is 0 and the filtered output value has overflowed (in relation to
the circular length), the output
Over/Und
is set to 1 for one cycle. When an
underflow occurs (in relation to the circular length), the output
Over/Und
is
set to -1.
Inputs
No. Name
Datatype Scaling
Description
1
XMstrLim
P64
Skal.-Fkt. 19
Continuous master position
2
XMstrEnd
P64
Skal.-Fkt. 19
Master position converted to circular length
3
MstrVel
I32
Skal.-Fkt. 20
Master speed
4
Over/Und
I8 –
Overflow/Underflow input
Expects a 1 if the master position in input
XMstrEnd
has overflowed
as per circular length during the last cycle, or a -1 if an underflow
occurred. Otherwise 0.
5
XLimNk
P64 Skal.-Fkt.
19
Continuous master position without offset, based on time stamp of the
encoder evaluation.
6
XEndNK
P64 Skal.-Fkt.
19
Master position converted to circular length without offset, based on
time stamp of the encoder evaluation.
13
Init
B –
Initialization of the actual master filter. Must always be triggered when
there is a jump in the master position (e.g., due to re-
parameterization).
Outputs
No. Name
Datatype Scaling
Description
7
XMstrLim
P64
Skal.-Fkt. 19
Continuous master position
8
XMstrEnd
P64
Skal.-Fkt. 19
Master position converted to circular length
9
MstrVel
I32
Skal.-Fkt. 20
Master speed
10
Over/Und
I8 –
Overflow/Underflow input
Expects a 1 if the master position in input
XMstrEnd
has overflowed
as per circular length during the last cycle, or a -1 if an underflow
occurred. Otherwise 0.
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...