Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
523
100944 Range Control 2
Description
The block performs range control.
The value of the parameter entered in
D70
is read, multiplied by
D71
and filtered with
the time constant
D72
by a low pass. The result is written to
D79
and transferred to
range control.
Range control checks to determine in which of the five following ranges the value is
located and switches one of the five outputs to
1:active
. If the limits are correctly
specified (
D74
<
D75
<
D76
<
D77
), the following reactions occur.
D79
>
D77
is
1:active
D76
<
D79
≤
D77
is
1:active
D75
≤
D79
≤
D76
Ar2GRN
is
1:active
D74
≤
D79
<
D75
Ar2YEL-
is
1:active
D79
<
D74
Ar2RED-
is
1:active
The sequence of the check is shown by the numbering below. In particular this
specifies the reactions of the block when the inputs are not sorted as per
D74
<
D75
<
D76
<
D77
.
1
D79
>
D77
,
D199
is
1:active
2
D79
>
D76
,
D198
is
1:active
3
D79
<
D75
AreaRED-,
D197
is
1:active
4
D79
<
D74
AreaYEL-,
D196
is
1:active
5
Otherwise:
AreaGRN
,
D195
is
1:active
Parameter
D73
can be used to enable the creation of an absolute value.
Range control can be disabled by the signal on the input
Reset
.
Range control can also be disabled based on parameter
D78
. When
D78
is set to
0:inactive
, range control is disabled when
A900
=
0:inactive
or one of the signals on
AccActiv
or
DecActiv
is active. This can be used, for example, to disable range
control during accelerating or decelerating procedures. When
D78
is set to
1:active
,
range control is always calculated.
Inputs
No. Name
Datatype Scaling
Description
1
AccActiv
B
–
Signal for suppressing range control (e.g., acceleration active)
2
DecActiv
B
–
Signal for suppressing range control (e.g., deceleration active)
3
Reset
B
–
Direct signal for suppressing range control
Outputs
No. Name
Datatype Scaling
Description
4
B –
D79
>
D77
,
D199
=
1:active
and application event 3 is triggered
5
B
–
D76 < D79 <
D77, D198 = 1:active
6
Ar2GRN
B –
D75
≤
D79
≤
D76
,
D197
=
1:active
7
Ar2YEL-
B –
D74
≤
D79
<
D75
,
D196
=
1:active
8
Ar2RED-
B –
D79
<
D74
,
D195
=
1:active
and event 2 is triggered
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...
Page 588: ...Notes Block descriptions ID 441692 01 www stoeber de STÖBER ANTRIEBSTECHNIK ...