System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
171
175 Controlled negate I32
Description
The block executes a controlled negation. When signal 0 is written to the input
Ctrl
, the value on
In
is output unchanged to
Out
. When
Ctrl
contains signal 1, the value on
In
is negated and
written to
Out
.
Exception: When the value on
In
is -2147483648 and the input
Ctrl
has signal 1, the value
2147483647 is written to
Out
.
Inputs
No. Name
Datatype Scaling
Description
1
In
I32 –
Input
value
2
Ctrl
B
–
Control input which controls the negation
Outputs
No. Name
Datatype Scaling
Description
3
Out
I32 –
Output
value
Summary of Contents for POSIDRIVE MDS 5000