System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
246
326 Falling edge detector
Description
The block determines a change in edge on the input
In
. With a falling edge, the output
Out
is set
to signal 1 for one cycle. Output
OldIn
is used for the computations of the block.
Inputs
No. Name
Datatype Scaling
Description
1
In
B –
Input
value
Outputs
No. Name
Datatype Scaling
Description
2
Out
B –
Indication of a falling edge:
0 = no falling edge found
1 = falling edge found
3
OldIn
B
–
For internal block calculations