Organization blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
13
8000001 Parameter
Description
The block supplies the value or address of the specified parameter.
It is mainly used to connect the current value of a parameter to block inputs. Remember that the value is
output unscaled and a PreRead function which may be assigned to the parameter is not called.
In addition, the block can be connected to the
ParAdr
input of blocks 192 to 197, 397 to 398 and 418 to
423 and the block supplies the address information of the specified parameter. These write accesses are
also unscaled and a PostWrite function which may be assigned is not called.
NOTE
To specify a parameter on the block, double click the block in the configuration interface with the left
mouse button (configuration interface must be in edit mode!). Then enter coordinate of the parameter.
Outputs
No. Name
Datatype Scaling
Description
1
–
–
Value/address of the parameter specified on the block