System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
278
397 Write parameter String8
Description
The block writes the value of input
In
to the parameter connected to the input
ParAdr
. The input
value is copied directly to the address and no parameter write function is used. Post-write functions
are not used. There is also no scaling or limit value check.
All characters down to the first binary 0 are copied, but not more than 8 characters.
Inputs
No. Name
Datatype Scaling
Description
1
ParAdr
Str8
–
Parameter to which a write access is made
2
In
Str8
–
Value to be written to the parameter
Summary of Contents for POSIDRIVE MDS 5000
Page 1: ...from V 5 6 D 02 2012 DE DESCRIPTION 5th generation of STÖBER inverters Blocks ...
Page 12: ...Organization blocks Block descriptions ID 441692 01 www stoeber de 11 STÖBER ANTRIEBSTECHNIK ...
Page 22: ...System blocks Block descriptions ID 441692 01 www stoeber de 21 STÖBER ANTRIEBSTECHNIK ...
Page 322: ...Standard blocks Block descriptions ID 441692 01 www stoeber de 321 STÖBER ANTRIEBSTECHNIK ...