100189 Fast Reference Value (output block)
Description
The block provides
D200
speed reference status word and supplies the binary and analog outputs.
With its interface it can be used on block 100191.
NOTE
The block is automatically used in the configuration of the axis when you generate the fast reference
value application.
Inputs
No. Name
Datatype Scaling
Description
1
Stndstil
B –
This signal is used in
D200
bit 0. The fast reference value application
uses the signal to indicate that the actual motor speed has reached
the value 0 Upm +-
C40
.
2
RefValRe
B –
This signal is used in
D200
bit 1 The fast reference value application
uses the signal to indicate that the ramp generator has reached its
reference value.
3
TorqueLi
B –
This signal is used in
D200
, bit 2. The fast reference value application
uses the signal to indicate that the positive or negative torque limit
has been reached.