Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
447
100808 X100.AE2 scaled
Description
The block supplies the value of the analog input and writes it to
E11
AE2-Level. The value is added
to
F21
AE2-Offset and then multiplied by
F22
AE2-gain.
Then a low-pass filter is performed with the time constant
F23
AE2 ref low pass filter to smooth the
reference value. The filtered value is output to the output
Out
and indicated in
E72
AE2 scale.
The block offers the parameters
E11
,
E72
,
F21
,
F22
and
F23
.
Outputs
No. Name
Datatype Scaling
Description
1
Out
I16
16384 = 100%
The output supplies the value of
E72
AE2 scale.