Standard blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
529
100950 Enable via reference
Description
The block generates a reference value enable for several reference values.
The block makes a bitwise AND-comparison of the input signal
RefVEna
and the
parameter
D55
. If the result is not zero or if
D55
=
0:inactive
, the output signal
RefVEna
is set to
1:active.
If bit 3 of the result of the bitwise AND-comparison and the input
Stop
are active,
the output signal
JogRefEna
is set to
1:active
.
Inputs
No. Name
Datatype Scaling
Description
1
RVEnaIn
U8 –
Summation signal of the individual reference value enables (similar to
D55
)
4
Stop
B –
Stop
signal
Outputs
No. Name
Datatype Scaling
Description
2
RVEnaOut
B
–
Reference value enable
3
JogRefEn
B
–
Jog reference value enable via reference value