System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
273
9
MotionID
U16
–
Comparison value of MotionID
10
PLCOstat
U8
–
Connection for PLCopen state code. Is not evaluated at this time.
13
SwtchPos
P64
Skal.-Fkt. 8
Switching position
14
Reset
B
–
Reset signal: 0 = normal operation, 1= reset switching point
Outputs
No. Name
Datatype Scaling
Description
3
Internal
I32
–
Intermediate storage for the actual position
4
Q_pulse
B
–
Pulse output only remains active for one cycle.
5
Q_Set
B
–
Static output remains active after the event up to the reset.
11
InState
U8 –
Not
used
12
OutState
U8
–
State of the output. Same as static output at this time.