System blocks
Block descriptions
ID 441692.01
STÖBER ANTRIEBSTECHNIK
281
400 Comparator U16
Description
The block compares the values on the inputs
In1
and
In2
. The result determines the output
to be set.
1. The values are equal. Output
In1=In2
is set.
2.
The value on
In1
is greater than the value on
In2
. Output
In1>In2
is set.
3.
The value on
In1
is less than the value on
In2
. Output
In1<In2
is set.
Inputs
No. Name
Datatype Scaling
Description
1
In1
U16
–
First input value
2
In2
U16
–
Second input value
Outputs
No. Name
Datatype Scaling
Description
3
In1=In2
B –
First result.
0=
In1
and
In2
are not equal.
1=
In1
and
In2
are equal.
4
In1>In2
B –
Second result.
0=
In1
is less than or equal to
In2
.
1=
In1
is greater than
In2
.
5
In1<In2
B –
Third result.
0=
In1
is greater than or equal to
In2
.
1=
In1
is less than
In2
.
Summary of Contents for POSIDRIVE MDS 5000