Communication
11.4 Communication via MODBUS TCP
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
857
11.4
Communication via MODBUS TCP
11.4.1
Overview
The Modbus protocol is a communication protocol based on a controller/device architecture.
Modbus offers three transmission modes:
●
Modbus ASCII - via a serial interface
data in the ASCII code. The data throughput is lower compared to RTU.
●
Modbus RTU - via a serial interface
data in the binary format. The data throughput is greater than in ASCII code.
●
Modbus TCP - via Ethernet
data as TCP/IP packages. TCP port 502 is reserved for Modbus TCP.
Only transfer type "Modbus TCP" is available for SINAMICS S120.
Possible drive units:
●
CU320-2 PN
●
CU320-2 DP (CBE20)
●
CU310-2 PN
Modbus functionality
Process data and parameters are accessed via the Modbus register.
●
Process data: 40100 - 40119
●
Drive data: 40300 - 40522
●
All parameters via DS47: 40601 - 40722
Modbus TCP always provides a basic Ethernet functionality, which corresponds to the
functionality of Ethernet interface X127:
●
Commissioning access for STARTER/Startdrive with S7 protocol
●
DCP to set the IP address etc.
●
SNMP for identification