Basic information about the drive system
13.12 System rules, sampling times and DRIVE-CLiQ wiring
Drive functions
1018
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
●
For mixed operation of the servo control and vector V/f control operating modes, separate
DRIVE-CLiQ lines should be used for the Motor Modules.
●
A Power Module with the CUA31/CUA32 should be connected to the middle or end of the
DRIVE-CLiQ line.
Figure 13-25 DRIVE-CLiQ line example
Encoder, Sensor Modules
●
The motor encoder or Sensor Module should be connected to the associated Motor
Module.
Connecting the motor encoder via DRIVE-CLiQ:
–
Single Motor Module Booksize to terminal X202
–
Double Motor Module Booksize motor X1 to terminal X202 and motor X2 to terminal
X203
–
Single Motor Module chassis to terminal X402
–
Power Module blocksize with CUA31: Encoder to terminal X202
–
Power Module blocksize with CU310-2: Encoder to terminal X100 or to terminal X501
of a Terminal Module
–
Power Module chassis to terminal X402
●
If possible, Sensor Modules of direct measuring systems should not be connected to the
DRIVE-CLiQ line of Motor Modules, but rather to free DRIVE-CLiQ sockets of the Control
Unit.
Note
This restriction does not apply to star-type connections for the Motor Modules.