Extended setpoint channel
3.4 Speed setpoint
Drive functions
72
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Overview of important parameters (see SINAMICS S120/S150 List Manual)
•
p1055[0...n]
BI: Jog bit 0
•
p1056[0...n]
BI: Jog bit 1
•
p1058[0...n]
Jog 1 speed setpoint
•
p1059[0...n]
Jog 2 speed setpoint
•
p1082[0...n]
Maximum speed
•
p1120[0...n]
Ramp-function generator ramp-up time
•
p1121[0...n]
Ramp-function generator ramp-down time
3.4.3
Direction of rotation limiting and direction reversal
A reversing operation involves a direction of rotation reversal. Selecting setpoint inversion
p1113[C] can reverse the direction of rotation in the setpoint channel.
Parameter p1110[C] or p1111[C] can be set respectively to prevent input of a negative or
positive setpoint via the setpoint channel. However, the following settings for minimum speed
(p1080) in the setpoint channel are still operative. With the minimum speed, the motor can
turn in a negative direction, although p1110 = 1 is set.
Figure 3-6
Direction of rotation limiting and direction of rotation reversal