Extended setpoint channel
3.5 Speed limiting
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
75
Function diagrams (see SINAMICS S120/S150 List Manual)
•
3001
Setpoint channel overview
•
3050
Setpoint channel - Skip frequency bands and speed limiting
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Setpoint limitation
•
p1080[0...n]
Minimum speed
•
p1082[0...n]
Maximum speed
•
p1083[0...n]
CO: Speed limit in positive direction of rotation
•
r1084
CO: Speed limit positive effective
•
p1085[0...n]
CI: Speed limit in positive direction of rotation
•
p1086[0...n]
CO: Speed limit in negative direction of rotation
•
r1087
CO: Speed limit negative effective
•
p1088[0...n]
CI: Speed limit in negative direction of rotation
•
p1106[0...n]
CI: Minimum speed signal source
•
r1119
CO: Ramp-function generator setpoint at the input
Skip frequency bands
•
p1091[0...n]
Skip speed 1
...
•
p1094[0...n]
Skip speed 4
•
p1101[0...n]
Skip speed bandwidth