Appendix
A.3 Supported sample topologies
Drive functions
1052
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
A.3.5
Topology example: Drives in V/f control (vector control)
The following diagram shows the maximum number of controllable vector V/f drives with
additional components. The sampling times of individual system components are:
●
Active Line Module: p0115[0] = 250 µs
●
Motor Modules: p0115[0] = 500 µs
●
Terminal Module/Terminal Board p4099 = 2 ms
Figure A-7 Topology example of a vector drive line-up in V/f control