Communication
11.3 Communication via PROFINET IO
Drive functions
850
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
PROFIenergy query commands
Query commands
Description
List_Energy_Saving_Modes
Determines all supported energy-saving modes.
Get_Mode
Determines the energy-saving mode.
PEM_Status
Determines the current PROFIenergy status.
PEM_Status_with_CTTO
Determines the actual PROFIenergy status, the same as for
the command "PEM status" and in addition with the regular
transition time to the operating state.
PE_Identify
Determines the supported PROFIenergy commands.
Query_Version
Shows the implemented PROFIenergy profile.
Get_Measurement_List
Returns the measured value IDs that can be accessed using
the "Get_Measurement_Values" command.
Get_Measurement_List_with_object
_number
Returns the measured value IDs and the associated object
number that can be accessed using the
"Get_Measurement_Values_with_object_number" command.
Get_Measurement_Values
Returns the requested measured value using the measured
value ID:
•
For power measured values:
The command addresses the sum of the measured value
over all control drive objects.
•
For energy measured values:
The command returns the sum of the measured value over
all control drive objects.
•
For power factors:
This measured value is supported only for a SINAMICS
with a control drive object.
Get_Measurement_Values_with_obj
ect_number
Returns the requested measured values using the measured
value ID and the object number. The object number corre-
sponds to the drive object ID.
The drive object ID of the Control Unit is used to address the
measured values as with "Get_Measurement_Value".