Function modules
8.2 Extended monitoring functions
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
473
Function diagrams (see SINAMICS S120/S150 List Manual)
•
8010
Signals and monitoring functions - Speed messages 1
•
8011
Signals and monitoring functions - Speed messages 2
•
8013
Signals and monitoring functions - Load monitoring (r0108.17 = 1)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Load monitoring
•
p2181[0...n]
Load monitoring, response
•
p2182[0...n]
Load monitoring, speed threshold 1
•
p2183[0...n]
Load monitoring, speed threshold 2
•
p2184[0...n]
Load monitoring, speed threshold 3
•
p2185[0...n]
Load monitoring, torque threshold 1, upper
...
•
p2190[0...n]
Load monitoring torque threshold 3, lower
•
p2192[0...n]
Load monitoring, delay time
Speed setpoint monitoring
•
p2150[0...n]
Hysteresis speed 3
•
p2151[0...n]
CI: Speed setpoint for messages
•
p2161[0...n]
Speed threshold 3
•
r2198.4
CO/BO: Status word, monitoring 2;
|n_set| ≤ p2161
•
r2198.5
CO/BO: Status word, monitoring 2;
n_set < 0