Safety Integrated Basic Functions
10.11 Acceptance test and acceptance report
Drive functions
718
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
10.11.1.1
Content of the complete acceptance test
A) Documentation
Documentation of the machine and safety functions
1.
Machine description (with overview)
2.
Specification of the controller (if this exists)
3.
Configuration diagram
4.
Function table:
–
Active monitoring functions depending on the operating mode and the protective door
–
Other sensors with protective functions
–
The table is part or is the result of the configuring work
5.
SI functions for each drive
6.
Information about safety equipment
B) Functional testing of safety functions
Detailed function test and evaluation of SI functions used. For some functions this contains
trace recordings of individual parameters. The procedure is described in detail in section
Acceptance tests (Page 724).
When testing the functions STO, SS1 and SBC, you do not have to make any trace
recording.
C) Functional testing of the forced checking procedure
Testing the forced checking procedure of the safety functions on each drive (for each control
type).
●
Testing the forced checking procedure of the safety function on the drive
–
If you are using Basic Functions, you need to activate and then deactivate STO once
again.
–
If you are using Extended Functions, you need to carry out a test stop / forced
checking procedure.
D) Conclusion of the report
Report of the commissioning status tested and countersignatures
1.
Inspection of SI parameters
2.
Logging of checksums (for each drive)
3.
Issuing of the Safety password and documenting this process (do not specify the Safety
password in the report!)
4.
RAM to ROM backup, upload of project data to STARTER and backup of the project
5.
Countersignature