Infeed
2.1 Active Infeed
Drive functions
30
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
2.1
Active Infeed
Features
●
Controlled DC link voltage whose level can be adjusted (independent of line voltage
fluctuations)
●
Regenerative feedback capability
●
Specific reactive current setting
●
Low line harmonics, sinusoidal line current (cos
φ
= 1)
●
Several Active Line Modules connected in parallel
●
Master/Slave operation for several Active Line Modules
●
Parameterizable bandstop filters for Active Line Modules in chassis format
Description
The Active Infeed closed-loop control works in conjunction with the line reactor or an Active
Interface Module and the Active Line Module as step-up controller. The level of the DC link
voltage can be defined through parameters, and, by means of the control, it is independent
of line voltage fluctuations.
The open and closed-loop control firmware of the Active Line Module runs on the Control
Unit assigned to it. The Active Line Module and Control Unit communicate via DRIVE-CLiQ.
The operating modes "parallel connection" and "master/slave connection" of the power units
are described in this manual in Section "Function modules (Page 465)".