Communication
11.3 Communication via PROFINET IO
Drive functions
852
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
11.3.10.5
PROFIenergy inhibit and pause time
Block PROFIenergy
If you set p5611.0 = 1, you inhibit the response of the inverter to PROFIenergy control
commands. In this case, the converter ignores the PROFIenergy control commands.
Pause time
●
Minimum pause time: p5602
–
When the pause time, which is sent using command "Start_Pause", is equal to or
greater than the value in p5602[1], then the inverter goes into the energy-saving
mode.
–
If the pause time is less than p5602[1], the inverter ignores the command.
●
Maximum duration: p5606
11.3.10.6
Function diagrams and parameters
Function diagrams (see SINAMICS S120/S150 List Manual)
•
2381
PROFIenergy - Control commands / query commands
•
2382
PROFIenergy - States
•
2610
Sequence control - Sequencer
Overview of important parameters (see SINAMICS S120/S150 List Manual)
•
r5600
Pe hibernation ID
•
p5602[0...1]
Pe hibernation pause time, minimum
•
p5606[0...1]
Pe hibernation duration, maximum
•
p5611
Pe energy-saving properties, general
•
r5613.0...1
CO/BO: Pe energy-saving active/inactive