Applications
12.2 Infeed switch on by a drive
Drive functions
916
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
●
The ON command (p0840) for the Infeed Module is generated via the binector output
"control contactor" of the "SERVO/VECTOR" drive object (p0863.1).
It is AND’ed with the negated binector output "Switching on inhibited" of drive object
"X_INF" (r0899.6) so that when the Control Unit restarts (powers up after the 24 V
returns), the necessary signal edge is generated.
●
The switch-on attempt is interrupted if, during the restart, a fault occurs in the Infeed
Module (drive object X_INF).
●
A fault in drive object "X_INF" is communicated to the "SERVO/VECTOR" drive object via
the BICO connection from p1208.0 to r2139.3 shown above.
●
The automatic restart of the X_INF drive object has absolutely no significance for the
described switch-on version. It is deactivated for drive object "X_INF".
WARNING
Unplanned motion when the automatic restart function is active
When the automatic restart is activated, when the line supply returns, unexpected motion
can occur that may result in death or serious injury.
•
Take the appropriate measures on the plant/system side so that there is no safety risk
as a result of an unexpected restart.
Overview of important parameters (see SINAMICS S120/S150 List Manual)
•
r0863.0...2
CO/BO: Drive coupling status word / control word
•
p0864
BI: Infeed operation
•
p0840[0...n]
BI: ON/OFF (OFF1)
•
r0899.0...15
CO/BO: Status word sequence control
•
p1200[0...n]
Flying restart operating mode
•
p1207
BI: Automatic restart (AR) - connection to the following drive object
•
p1208[0...1]
BI: Automatic restart modification, infeed
•
p1210
Automatic restart mode
•
r1214.0...15
CO/BO: Automatic restart status
•
p2105[0...n]
BI: 3. Acknowledge faults
•
r2139.0...15
CO/BO: Status word, faults/alarms 1
•
p2810[0...1]
BI: AND logic operation inputs
•
r2811.0
CO/BO: AND logic operation result
•
p2822[0...3]
BI: NOT logic operation input
•
r2823.0...3
CO/BO: NOT logic operation result
Summary of Contents for SINAMICS S120
Page 1: ......
Page 2: ......
Page 24: ...Contents Drive functions 24 Function Manual 11 2017 6SL3097 4AB00 0BP5 ...
Page 932: ......
Page 1094: ......