Communication
11.1 Communication according to PROFIdrive
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
757
Error
value
Meaning
Remark
Additional
info
0x07
Description element cannot be
changed.
Modification access to a description element that cannot be
changed.
Subindex
0x09
No description data available.
Access to a description that does not exist (the parameter
value exists).
–
0x10
Read job will not be executed.
The read request is refused because know-how protection is
active.
0x0B
No operating priority.
Modification access with no operating priority.
–
0x0F
No text array exists.
Access to a text array that does not exist (the parameter
value exists).
–
0x11
Request cannot be executed due to
operating status.
Access is temporarily not possible for unspecified reasons.
–
0x14
Illegal value.
Modification access with a value that is within the limits but
is illegal for other permanent reasons (parameter with de-
fined individual values).
Subindex
0x15
Response too long.
The length of the present response exceeds the maximum
transfer length.
–
0x16
Illegal parameter address.
Illegal or unsupported value for attribute, number of ele-
ments, parameter number, subindex or a combination of
these.
–
0x17
Illegal format.
Write request: Illegal or unsupported parameter data format. –
0x18
Number of values inconsistent.
Write request: A mismatch exists between the number of
values in the parameter data and the number of elements in
the parameter address.
–
0x19
Drive object does not exist.
You have attempted to access a drive object that does not
exist.
–
0x20
Parameter text cannot be changed
–
–
0x21
Service not supported.
Illegal or unknown request ID
–
0x65
Parameter presently deactivated.
You have tried to access a parameter that, although availa-
ble, does not currently perform a function (e.g. n control set
and access to a V/f control parameter).
–
0x6B
Write access for the enabled control-
ler.
Write access is possible while the device is in the "Controller
enable" state.
Pay attention to the parameter attribute "changeable" in the
SINAMICS S120/S150 List Manual (C1, C2, U, T).
–
0x6C
Parameter %s [%s]: Unknown unit.
–
–
0x6D
Parameter %s [%s]: Write access
only in the commissioning state,
encoder (p0010 = 4).
–
–
0x6E
Parameter %s [%s]: Write access
only in the commissioning state,
motor (p0010 = 3).
–
–
0x6F
Parameter %s [%s]: Write access
only in the commissioning state,
power unit (p0010 = 2).
–
–
0x70
Parameter %s [%s]: Write access
only in the quick commissioning
mode (p0010 = 1).
–
–