Function Manual, 11/2017, 6SL3097-4AB00-0BP5
929
Instructions for offline commissioning with STARTER
With automatic online configuration in STARTER, the DMC20 is detected and integrated in
the topology. The following steps must be taken to commission offline:
1.
Configure the offline drive device.
2.
Right-click "Topology" in the project navigator and call the "Add new object > DRIVE-
CLiQ hub" context menu.
3.
Configure the topology.
Overview of important parameters (see SINAMICS S120/S150 List Manual)
•
p0105
Activate/deactivate drive object
•
r0106
Drive object active/inactive
•
p0151[0...1] DRIVE-CLiQ Hub Module component number
•
p0154
DRIVE-CLiQ Hub Module detection via LED
•
r0157
DRIVE-CLiQ Hub Module EEPROM data version
•
r0158
DRIVE-CLiQ Hub Module firmware version
•
r0896.0
BO: Parking axis status word
•
p0897
BI: Parking axis selection