Appendix
A.7 Functions of SINAMICS S120 Combi
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
1081
Topology
Fixed DRIVE-CLiQ topology rules for SINAMICS S120 Combi. The device must always be
connected according to the same principle.
System clocks
The sampling times are permanently set to 125
μs for the following functions:
●
Current controller
●
Speed controller and
●
Flux controller
The pulse frequency is permanently set to 4 kHz. This means that a maximum spindle speed
of 24000 rpm can be reached.
Available motors
●
Synchronous motors: 1FE1, 1FT6, 1FT7, 1FK7, 1FW6
●
Induction motors: 1PH7, 1PH4, 1PL6, 1PH8