Programming the Technological Functions
6-40
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
The functions which can be activated in the FM using single settings or single com-
mands are listed below.
Single Settings
Single Commands
Servo enable
On-the-fly measuring
Rotational speed monitoring
Parking axis
Simulation
Length measuring
Retriggering of reference point
Reset Enable input
Disable software limit position monitoring
Activate machine data
Delete distance to go
Automatic block return
Automatic block advance
Restart
Rescind set actual value
Error messages from the FM
When an operator error, traversing error or data error occurs, the error number is
read automatically via a Read request. The error number is entered in the AW-DB
user data block and the Read status set.
An operating error, reported via a diagnostic interrupt, can be read out with the
Read request “Operating error no.” (AW-DB, DBX42.5).
Table 6-9
Error messages from the FM
Error
Message
Error No.
Error Acknowl-
edgement
Data error
Status signal
(AW-DB, DBX22.4)
Is read out via Read re-
quest
(AW-DB, DBB94 and 95)
New Write request
Operator/travers-
ing error
Status signal
(AW-DB, DBX22.3)
Is read out via Read re-
quest
(AW-DB, DBB 90 and 91)
Set/reset control
signal “Acknowl-
edge operator/tra-
versing error” (AW-
DB, DBX14.3)
Diagnostic inter-
rupt
Activated with
OB 82, the data
must be read out
using the
POS_DIAG block
In case of an operating
error read out via the
POS_DIAG block, the error
no. is read out via the
Read request DBX42.5
(AW-DB, DBB86 and 87)
Single command:
Restart
For additional specific information, please refer to Chapter 11 “Error Handling”.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...