Writing Traversing Programs
10-3
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Skip block /
Program blocks which are not to be executed every time the program runs can be
identified as skippable blocks by an oblique “/ ”. When the program is being pro-
cessed, the “Skip block” control signal can be used to decide whether skippable
blocks are to be skipped. The last block may not be skipped.
Block number N
The program is executed in ascending order of block numbers (1 to 255) or in de-
scending order if executed in reverse.
G function group 1
−
3
In each traversing block only one G function may be entered from each G function
group.
The following figure shows an example.
/
N G1
G2
G3
X/t
F
M1
M2
M3
D
400 00
100 000
10
90
43
34
10
G functions
Table 10-1 lists the possible G functions and the individual G function groups.
Table 10-1
G functions
GNo.
G Function
G Function
group
04
1)
Dwell time
87
Turn off measuring system shift for Set Actual Value On-the-Fly
88
1)
Continuous travel for (
−
) for Set Actual Value On-the-Fly
1
89
1)
Continuous travel for (+) for Set Actual Value On-the-Fly
1
90
Absolute dimensions
91
Incremental dimensions
30
31
32
.
.
.
39
100% override on acceleration/deceleration
10% override on acceleration/deceleration
20% override on acceleration/deceleration
.
.
.
90% override on acceleration/deceleration
2
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...