Description of Functions
9-15
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
9.2.1
Jogging
Overview
In Jogging mode, axis traversing movements are specified by way of the direction
keys (R+ or R
−
) and by speed.
Velocity
Before the axis can be moved, speeds (velocities) 1 and 2 must first be transferred
to the FM 353 (user DB, DBX38.0).
You can choose between two mutually independent velocities (level 1 and level 2)
with the mode parameter (BP).
The velocity can also be controlled using the override, and can be changed during
the movement.
Name
Lower input limit
Upper input limit
Unit
Speed
10
500 000 000
MSR/min
MSR stands for measurement system raster (see Section 5.3.1)
Handling by the user
The table below gives you an overview of how to handle this mode.
Triggering of
movement, Direc-
tion (R)
Ievel selection
Speed
R+ or R
−
BP = 1
Value for speed level 1
R+ or R
“level-controlled”
BP = 2
Value for speed level 2
Note
Please see also Section 9.1.3!
Control actions
Preconditions:
S
The FM 353 has been initialized.
S
The mode has been selected and acknowledged.
S
Drive Enable [AF] = 1 (control signal in user DB, DBX15.7)
S
Stop [STP] = 0 (control signal in user DB, DBX15.1)
S
Servo Enable (RF) = 1 (user DB, DBX34.0)
S
Speed levels have been transferred.
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...