Programming the Technological Functions
6-47
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
User data block (AW-DB), continued
AW-DB
FM 353
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Byte
DBD28
Actual position
(with firmware version V3.7.6 and higher in conjunction with the blocks of the “FM353_354” library
DBW32
Reserved
Initiation signals
Initiation signals
Initiation signals for single settings (switches); transfer through Write request when change occurs
DBB34
Simulation
Parking
axis
Rotation
monitoring
In-process
measuring
Controller
enable
DBB35
Software
limit posi-
tions dis-
abled
Enable
input dis-
abled
Retrigger
ref. point
Length
measure-
ment
Initiation signals for single commands; transfer through Write request when change occurs
(signals are reset following transfer)
DBB36
Reserved
DBB37
Rescind
setting of
actual value
Restart
Automatic
block
return
Automatic
block ad-
vance
Delete
residual
distance
Activate
MD
Initiation signals for Write requests
DBB38
Set actual
value
Set refer-
ence point
On-the-fly
MDI block
MDI block
Setpoint for
incremental
dimension
Frequency
levels 1, 2
Speed
levels 1, 2
DBB39
Teach-in
Request
application
data
Program
selection
Digital
outputs
Modify pa-
rameters /
data
Zero offset
On-the-fly
setting of
actual value
DBB40
to
DBB41
Reserved
Initiation signals for Read requests
DBB42
Operating
error no.
Service
data
Actual
value block
change
Next
NC block
Active
NC block
Basic
operating
data
DBB43
Read
measured
values
Application
data
Additional
operating
data
Dig. inputs/
outputs
Parameter/
data
Summary of Contents for SIMATIC FM 353
Page 22: ...Product Overview 1 12 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 32: ...Installing and Removing 3 6 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 282: ...Description of Functions 9 82 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...
Page 354: ...User Data Block AW DB B 16 FM 353 Stepper Drive Positioning Module 6ES7 353 1AH01 8BG0 ...